Outdoor Substation 3 Pole 66kv Sf6 Gas Circuit Breaker with Spring Mechanism

Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: SF6
Installation: Fixed
Type: Circuit Breaker
Customization:

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
LW36-66
Function
Circuit-Breaker Failure Protection
Certification
VDE, ISO9001-2000, CE
Brand Name
L&R or as Per Clients′ Requirements
Size
Any Size Can Be Ordered
OEM&ODM
Accept
Transport Package
Export Standard Package or as Client Requirement
Specification
ISO9001: 2008
Trademark
L&R or according to customer′s requirement
Origin
Wenzhou, Zhejiang
Production Capacity
20, 000PCS/Month

Product Description

Overview:
L&R developed LW-40.5/72.5/126/145 series of outdoor SF6 gas circuit breaker using modern processing technology and comper-aided design techniques, combined with the latest generation of spring bodies and the advantages of a permanent institution,.Its pursuit of high reliability, easy to maintain design concepts to create a generation of L&R all series switches meet the following criteria.
ANSI/IEEE G37.60/IEC 62271-100( GB1984-2003 China standard)
GBT11022-11
IEC 60255-21-1 Class I
IEC 60255-21-2 Class I
IEC 60255-21-3 Class I
IEC 60255-22-1 Class III
IEC 60255-22-2 Class IV
IEC 60255-22-3 Class III
IEC 60255-22-4 Class IV

Main features
1, molecule sieva 2. porcelain insul. ator
3, nozzle 4 pressure cylinder
5, valve disc 6. piston
7, moving contact pedestal 8. pull rod
9, moving contact finger 10. main contact
10, moving arc contact 12. fixed arc contact
13, fixed contact finger
14, fixed contact pedestal
 
Name Unit parameter
reted voltage kv 40.5 72.5 126 145
rated frequency Hz 50/60
rated current  A 1250,......4000
1min power frequency withstand voltage KV 95/118 140 230 265
lightning impulse withstand voltage KV 215 325 550 650
5min power frequency voltage at zero gas pressure KV 40.5 55 95 109
rated short circuit breaking current KV 63,.80 80,..100 80,..100 80,..100
rated short breaking current KV 21,...31.5 31.5,...40 31.5,...40 31.5,...40
rated out-of-phase breaking current KV 8/10 10 10 10
rated cable(line) charging breaking current A 31.5 10 31.5 50
rated gas pressure Mpa 0.4/0.15 0.4 0.5 0.5
main loop resistance μΩ ≤80 ≤40 ≤45 ≤45
operation sequence   O-0.3s-CO-180s-CO
SF6 gas leakage rate (per year) % ≤1
moisture content(v/v) ppm ≤150      
creepage distance across the open contacts mm 1256 2300 3950 ≥3950
to earth   1256 2300 3950 ≥3950
mechanical life times 10,000
Outdoor Substation 3 Pole 66kv Sf6 Gas Circuit Breaker with Spring MechanismOutdoor Substation 3 Pole 66kv Sf6 Gas Circuit Breaker with Spring MechanismOutdoor Substation 3 Pole 66kv Sf6 Gas Circuit Breaker with Spring MechanismOutdoor Substation 3 Pole 66kv Sf6 Gas Circuit Breaker with Spring MechanismOutdoor Substation 3 Pole 66kv Sf6 Gas Circuit Breaker with Spring Mechanism

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
77
Management System Certification
OHSAS18001:2007, ISO9001:2015, ISO14001:2015