• High Voltage Polymeric Metal Zinc Oxide Lightning Surge Arrester for Transmission and Distribution Work
  • High Voltage Polymeric Metal Zinc Oxide Lightning Surge Arrester for Transmission and Distribution Work
  • High Voltage Polymeric Metal Zinc Oxide Lightning Surge Arrester for Transmission and Distribution Work
  • High Voltage Polymeric Metal Zinc Oxide Lightning Surge Arrester for Transmission and Distribution Work
  • High Voltage Polymeric Metal Zinc Oxide Lightning Surge Arrester for Transmission and Distribution Work

High Voltage Polymeric Metal Zinc Oxide Lightning Surge Arrester for Transmission and Distribution Work

Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Installation: Parallel Arrester
Application: AC/DC System
Size: Meidum
Operation Voltage: High Voltage
Customization:

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
Lighting Arresters
Shape
Gyro Type
Material
Composite
Certification
ISO9001
Rated Voltage
54kv 60kv 66kv 72kv
Discharge Current
10ka
Creepage Distance
1260mm; 1465mm; 2255/2780mm
Transport Package
Standard  Export  Package
Specification
ISO9001: 2008
Trademark
L&R or according to customers requirements
Origin
Wenzhou, Zhejiang, China
Production Capacity
1000 Piece/Pieces Per Month

Product Description

Specifications
Place of Origin:Zhejiang, China (Mainland)
Brand Name:L&R
Model Number:Lighting Arresters
Type:Porcelain Surge Arrester
Warranty:2 Years
Rated Voltage:50kv 60kv 66kv 72kv
A.C Systems:20KA 10KA
Name:Surge Arrester
Product name:Arrester
Application:A.C Systems
Ambient air temperature:-40ºC ~ +60ºC
Altitude:≤ 3000m
Frequency:48Hz ~ 62Hz
Packaging & Delivery
Packaging Details:1 SET DROP OUT FUSE/WOODEN CARTON
Delivery Detail:3-5 days for small amount,10-20 days for large amount

What can we do for you?

1) Good quality guarantee (2 years).

2) Competitive Price (Factory direct price).

3) Agent service in all the world.

4) On time delivery .

5) We offer sample for free.

6) Professional Technology .

7) Quality Control through the whole Manufacturing process.

 a. Check the material before the production .

b. Have the random inspection during the production .

c. Make the 100% inspection before the shipment.
High Voltage Polymeric Metal Zinc Oxide Lightning Surge Arrester for Transmission and Distribution Work

High Voltage Polymeric Metal Zinc Oxide Lightning Surge Arrester for Transmission and Distribution Work

Model Meaning:

YH 10 W - YY - SC Z - OPTIONS
YH ------ Y-indicates porcelain housing, YH-indicates polymer housing
10  ------ 10kA-Discharge current
W   ------ W-indicates gapless
YY  ------ YY-rated voltage (kv)
SC Z ------ SC-applicable for station class only i.e. 'Z"-2, 3 or 4
OPTIONS  ------ 1. IBDD: ground lead disconnecting device Integrated in insulating bracket
                           2. LBO: I-bracket for mounting c/w bolts, Washers and lead for live terminal
                           3. CR: corona ring applicable to systenVoltages from 100kv and upwards
                           4. IBP: insulating base plate
                           5. BP-base plate only applicable from 40kv Upwards
                           6. ST12-st-m12 bolt c/w two nuts, washers & spring washer
                           7. ST26-st-stem type 26 Φ x 100mm top contact
                           8. ST38-st-stem type 38 Φ x 125mm top contact

                           9. PE-67 x 100mm flat l-shape top contact with 4 holes Φ 45mm centres

When Ordering Voltages Above 100Kv The Following Are STD

1. Corona Rings are STD component for voltages ranging from 100 kV and above.

2. Base Plates with insulating bases are to be only ordered or used when coupling them to Surge Counter applications.

3. Base plates are STD supply for voltages ranging from 42 kV and above.

Working Condition

1. Ambient air temperature: -40ºC ~ +60ºC ;

2. Altitude: ≤ 3000m;

3. Frequency: 48Hz ~ 62Hz;

4. Power frequency voltage applied between terminals of surge arrester must not exceed continuous operating voltage of surge arrester;

5. Earthquake (Seismic) intensity is less than 8 degree;

6. Max. Wind speed is 35m/s;

Model Rated  Voltage kV Continuous operating voltage (kV rms) Lightning  Impulse Residual voltage Under Norminal DischargeCurrent (≤ vKP) Line discharge class Creepage distance mm 2ms  Square  Wave  Impulse  Current  Withstand A 4/10μS  High  Current Impulse/kV
YH10W-54 54 42 160 2&3 1260 400 100
YH10W-60 60 48 178 2&3 1465 400 100
YH10W-66 66 52.8 196 2&3 1465 400 100
YH10W-72 72 57 214 2&3 2255/2780 400 100
High Voltage Polymeric Metal Zinc Oxide Lightning Surge Arrester for Transmission and Distribution WorkHigh Voltage Polymeric Metal Zinc Oxide Lightning Surge Arrester for Transmission and Distribution WorkHigh Voltage Polymeric Metal Zinc Oxide Lightning Surge Arrester for Transmission and Distribution WorkHigh Voltage Polymeric Metal Zinc Oxide Lightning Surge Arrester for Transmission and Distribution WorkHigh Voltage Polymeric Metal Zinc Oxide Lightning Surge Arrester for Transmission and Distribution Work

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
77
Management System Certification
OHSAS18001:2007, ISO9001:2015, ISO14001:2015