Basic info.
Certification:ISO9001 ; IEC
Export Markets:Global
Packaging: standard package or cilent's requirment
Brand name: L&R or as per clients' requirements
Main technical parameters:
FN12-12 and FN12-12R is of three phases indoor use AC high voltage load switch for breaking and making the circuit of 50Hz, 12KV system under rated loading, closed loop current, no-loading transformer, cable charged current and short circuit current. The load switch equipped with earth switch can withstand short circuit current, and m-ainly used in power distribution substation and industrial electrical equipment where three phase closed loop circuit or bottom power supply system for control and protection.
Standard
a,GB3804-903~65KV AC H.V Load switch
b,GBXXX-XXAC H.V load switch with fuse box(the same IEC420-1990)
c,GB1995-89AC H.V isolate switch and earth switch |
Normal Serviec Condition
A,The ambient air temperatrue : Max:+40. Min:-25.
B,The altitude ≤1000m.
C,The relatire humidity of air Daily average ≤95% . Monthly average ≤90%
D,The ambient air should not be obviously polluted by corrosivity or the flammability gas and geam.Etc.
E,Without frequent shake.
F,Enviroment degree : grade . |
Number |
Name |
Unit |
FN12-12D/630 |
FN12-12D(R)D/100 |
1 |
Rated voltage |
KV |
12 |
2 |
Rated frequency |
Hz |
50 |
3 |
Rated current |
A |
630 |
100 |
4 |
Lighting impulse resisting voltage |
KV |
To ground.interphase 75 isolation break 85 |
5 |
1min power frequency withstand voltage |
KV |
To ground.interphase 42 isolation break 48 |
6 |
Rated heat-stability current |
KA |
20(4S) |
7 |
Rated machine-stability current |
KA |
50 |
8 |
Rated closing current(peak) |
KA |
50 |
50 |
9 |
Rated short-circuit breaking current (prospective value) |
KA |
|
31.5 |
10 |
Max.critical breaking current |
A2S |
|
fuse box characterisitic curve |
11 |
Min.Breaking current |
KA |
|
fuse box characterisitic curve |
12 |
Rated transfer current |
KA |
|
1.5 |
13 |
Max.breaking current(reference value) |
KA |
1.8 |
14 |
Braking no-load transformer capcity |
kva |
1250 |
15 |
Rated cable charging current |
A |
10 |
16 |
Rated power load current breaking times |
time |
≥100 |
17 |
Switch-off time of rated power load current switch on-and-off |
S |
|
>0.06 |
18 |
Rated transfer current |
KA |
20(2S) |
20(2S) |
19 |
Rated transfer current |
KA |
50 |
50 |
20 |
Motor operating power valtage |
V |
pay 110,220 direct current |
|
|
|
Mechanical characteristic parameter
Nunber |
Name |
Unit |
FN12-12D/630 |
FN12-120D(R)D/100 |
1 |
Machine contact qeneral travel |
mm |
200±8-2 |
2 |
Interphase distance (before mechansim store energy) |
mm |
210±3 |
3 |
Dynamic contact ultra travel |
mm |
40±2 |
4 |
Auxiliary contact distance |
mm |
40±2 |
5 |
Three-phase switch on-and-off synchroneity |
m/s |
<3 |
6 |
Switch-off speed |
m/s |
>2.8 |
>2.8 |
7 |
Switch-on speed |
m/s |
>3.8 |
8 |
Distance between metal valueand conducting pipe |
mm |
>125 |
9 |
Earth switch fracture distance |
mm |
>150 |
10 |
Main.loop resistance |
μΩ |
<120 |
<300 |
11 |
Max.Opertaing moment |
Nm |
<160 |
|
Our Services
1. Rich experience in ODM and OEM
2. Excellent One-stop service
3. High Quality Precision Customized forging & Casting services
4. The best price
5. Strict quality control
6. We wormly welcome you come to visit our factory and seek further cooperation